Sika · Roof waterproofing
Sika Sikalastic-560 waterproof coating for exposed roofs
Sikalastic-560(Sikalastic-560)
You can buy materials separately from HK Create Design. Tell us the quantity and district to check unit prices, lead times and charges for kerbside delivery or delivery to your floor.
Sikalastic-560 is a one-part, water-based roof waterproofing coating made with Sika’s Co-Elastic Technology (CET). This polyurethane-modified acrylic dispersion is ready to use and cold-applied without a flame. It dries to form a seamless, highly elastic, UV-resistant membrane suitable for exposed roofs. The manufacturer lists new and refurbished roofs, complex roof details and extending the life of ageing roofs among its applications. The white version has an initial solar reflectance of 0.82 and a solar reflectance index (SRI) of 102. It reflects sunlight and can help reduce indoor temperatures. The product is listed in the Hong Kong Green Product Directory, with a VOC content below 50 g/L in line with Hong Kong Environmental Protection Department limits for architectural paints. The unreinforced system uses 2–3 coats with a total consumption of ≥ 0.9–1.4 kg/m² and a dry film thickness of ≥ 0.3–0.5 mm. The reinforced system incorporates Sikalastic Fleece-80 or glass-fibre fabric. The substrate must be dry, with a moisture content of ≤ 6% and no standing water. Air and substrate temperatures must be +8°C to +35°C, with relative humidity ≤ 80%. Each unreinforced coat must be no more than 0.75 kg/m². On village house or tenement roofs in Hong Kong, this exposed system can be recoated later without stripping the sound existing layer.

Buy materials: kerbside handover or delivery to your floor
Your quote lists the material price, transport and any charge for carrying the goods to your floor separately. Choose a delivery option to enquire.
Add other materials (optional)
Exposed roofs on village houses, tenements and top-floor flats
HK Create Design · Materials and delivery quotations: 5243 7747
How much Sikalastic-560 do I need per square metre of roof?
First check whether the project calls for a coating alone or a waterproofing system with reinforcing fabric. The two systems require different materials and quantities.
| Estimate item | How to allow for it in the quotation |
|---|---|
| Coating without reinforcing fabric | The manufacturer gives a total consumption of about 0.9–1.4 kg/m² for 2–3 coats. |
| Example: coating 20 m² without reinforcing fabric | At the rates above, allow about 18–28 kg, plus separate allowances for primer, reinforced areas and wastage. |
| System with reinforcing fabric | Measure the area of fabric, overlaps, parapet junctions and drain outlets separately. Calculate quantities for the corresponding manufacturer’s system. |
When comparing roof quotations, ask for separate items for substrate preparation, primer, reinforcing fabric and topcoat so you can compare the same scope of work.
Check the manufacturer's data sheet and application conditions
Sika Sikalastic-560 waterproof coating for exposed roofs · Application illustration
How is a continuous waterproof membrane formed on an exposed roof?


Illustration of the work sequence. Colour, finish and drying conditions vary on site.
- Material features
- The coating is applied cold and can follow complex corners. The completed system is UV-resistant and suitable for exposed roofs.
- Where to use it
- Roofs requiring an exposed waterproofing system, including those above top-floor flats and on village houses.
- Application method
- Check the substrate and primer. Reinforce joints and corners as specified for the system, then apply the coating in layers at the specified coverage rate.
Sikalastic-560 application steps
- The substrate must be sound, clean, dry and free of dirt and grease. Abrade it if necessary.
- On cementitious or masonry substrates, use Sikalastic-560 diluted with 10% water as a primer at about 0.3 kg/m². Allow it to dry until tack-free.
- Before use, stir for about 1 minute until uniform. Avoid excessive mixing, which can introduce air.
- Treat details such as drains, wall junctions and pipe penetrations first. Mask door frames and other areas requiring protection.
- Unreinforced coating: apply 2–3 coats. Allow time between coats according to the weather, about 4 hours at +30°C.
- Reinforced system: apply about 0.75–1.0 kg/m² and roll Fleece-80 into the wet coating, overlapping by at least 5 cm. Apply a further 0.25–0.5 kg/m² wet-on-wet. Once dry, seal with one or more coats of ≥ 0.5 kg/m² each.
- Clean tools immediately with water.
Manufacturer’s specifications
View Sikalastic-560 Manufacturer's information and sources
| Property | Specification |
|---|---|
| Chemical base | Polyurethane-modified acrylic dispersion (one-part, water-based) [1] |
| Packaging | 20 kg [1] |
| Colour | Gray, terracotta, red, white (Energy Star) [1] |
| Unreinforced coating system: consumption | 2–3 coats. Total consumption ≥ 0.9–1.4 kg/m², dry film thickness ≥ 0.3–0.5 mm. [1] |
| Maximum per coat | Each unreinforced layer shall not exceed 0.75 kg/m² [1] |
| Tensile strength | Approximately 1.5 N/mm² without reinforcement; approximately 12.0 N/mm² with Fleece-80 [1] |
| Solar reflectance (white, initial) | Solar reflectance 0.82, thermal emittance 0.93, SRI 102 [1] |
| VOC | < 50 g/L, in line with the Hong Kong Environmental Protection Department's architectural paint limit; included in the Hong Kong Environmentally Friendly Product List [1] |
| Application conditions | Air and substrate temperatures +8°C to +35°C, relative humidity ≤ 80%, substrate moisture content ≤ 6% [1] |
| Drying time (+30°C) | Touch-dry in about 1 hour, rain-resistant after about 4 hours and fully cured in about 2 days [1] |
| Primer for cementitious substrates | Sikalastic-560 is diluted with 10% water, about 0.3 kg/m² [1] |
| Shelf life | 18 months from production date [1] |
Suitable applications
- Exposed roofs on village houses, tenements and top-floor flats
- Refurbishing an ageing roof waterproofing system by recoating
- Roofs with complex shapes or numerous details
- Roofs where the white finish is used to reflect sunlight and reduce heat absorption
Applications to avoid
- Substrates that are damp, have standing water or have rising moisture
- Application during rain or when relative humidity exceeds 80%
- Painted substrates without an adhesion test
How we use this material on site
For roof waterproofing, we remove loose existing coating, repair cracks and treat drains and parapet junctions. Once the surface is dry, we apply diluted primer, reinforce the details with fleece and apply 2–3 coats.
View the work details Whole-home renovation in Hong Kong: stages, timing and budgetWhen the top floor unit is renovated, if there is water damage on the ceiling, we will also check the rooftop to avoid water seepage after renovation.
View the work detailsApplication notes
- The substrate temperature should be at least 3°C above the dew point.
- Storage temperature +5°C to +30°C, high temperatures will shorten shelf life.
Sika products
Specifications are drawn from manufacturers' websites or technical data sheets. Refer to the manufacturer's latest data sheet for updates. HK Create Design is independent of the brands shown. Brand names and trademarks belong to their owners.