01

How are extra sockets priced? By number of points.

We price sockets by point. HK$640 covers a new concealed 13 A single socket, chase, cable, back box, faceplate and filling. Double sockets, TV or data points are HK$1,200 each. A dedicated appliance circuit is HK$3,350.[1]

Check the HK$2,000 small-job minimum.[1] One HK$640 socket is charged at the HK$2,000 minimum. Three H02 outlets total HK$1,920 and are also charged at HK$2,000. Plan several required additions together where practical.

An extra socket can be connected to a suitable existing socket circuit. Major loads such as induction hobs, ovens and electric water heaters require separate circuit assessment. An additional dedicated circuit has different costs and safety requirements.

  • H02: HK$640 per set
  • H03: HK$1,200 per set
  • H06 HK$3,350/circuit
  • Minimum charge HK$2,000
Adding sockets: inclusions and exclusions

You can swipe left or right on your phone to view the complete table.

No.ItemCompany rateAlready includedExcluded or separately charged
H0213 A single socket with concealed conduitHK$640 per setChasing, wiring, back box, faceplate and filling the chaseChasing and repairing tiled walls, and repainting
H03Double socket, TV or data pointHK$1,200 per setChasing, wiring, back box, faceplate and filling the chaseNetworking equipment and router
H06Dedicated circuitHK$3,350 per circuitDedicated circuit with connection at the distribution boardIncrease entry capacity
H04Replace a light switch and its wiringHK$430 per unitRemove, replace and wire.Light fittings
—Small-job minimum chargeHK$2,000Small jobs for one or two outlets—

Our published rates. [1] [1]

02

Four examples: bedroom, kitchen, TV wall and a single extra point

Example 1: one socket at HK$640 falls below the minimum, so the charge is HK$2,000.[1] Example 2: three H02 outlets for bed and desk plus one data point: 3 × 640 + 1,200 = HK$3,120.[1]

Example 3: two dedicated circuits for an induction hob and oven plus four worktop sockets: 2 × 3,350 + 4 × 640 = HK$9,260.[1] Example 4: three H03 and two H02 points at the TV wall: 3 × 1,200 + 2 × 640 = HK$4,880.[1]

The four totals vary mainly with the need for dedicated circuits and the choice of H02 or H03. Ask for type and quantity per item to compare like scopes. See the calculations at the end.

  • State the number of points.
  • Distinguish H02, H03 and H06.
  • Use the same schedule for comparison.

03

Socket positions, room by room

A TV wall often serves the television, set-top box, audio and router. Consider double sockets plus a data point. EMSD advises separating power wiring from telephone, television and data cables.[2] Provide one socket on each side of the bed for chargers and lamps. Consider a data connection at the desk.

Allow for worktop appliances, the fridge and microwave. Avoid sockets near water pipes, gas pipes or the hob.[2] Use separate sockets for major appliances such as induction hobs and ovens, and assess dedicated circuits.

Take particular care in bathrooms. Locate sockets at least 0.6 m from the bath or shower basin and install switches for bathroom lights and similar fixtures outside.[2] Balconies and outdoor locations require weatherproof sockets.[2]

Decide bed, desk, sofa and TV cabinet positions before locating sockets. This helps avoid discovering a socket behind a fitted wardrobe after installation.

  • Choose the furniture positions first.
  • Separate power and data cables at the TV wall.
  • Keep kitchen sockets away from water pipes, gas pipes and hobs.
  • Bathroom clearance: 0.6 m
  • Use a weatherproof socket on the balcony.
Published prices for additional electrical points, 2026(Unit:HK$)
H06 dedicated circuit
HK$3,350
Small-job minimum charge
HK$2,000
H03 double socket, TV or data point
HK$1,200
H02 13 A socket
HK$640
H04 light switch with wiring
HK$430

Our published prices are preliminary references. [1]

「Agree furniture positions before adding outlets. Bedheads, desks, media units and kitchen worktops often lack enough sockets.」

HK Create Design electrical works supervisor
Completed custom media wall cabinets and pendant light in a living room
Project photo: double sockets and a data point at a TV wall, with power and communications cables routed separately. Select an image to enlarge

04

When do I need a dedicated circuit instead of just another socket?

An existing general socket circuit may serve low-power appliances such as phones, computers and TVs. Higher-load hobs, ovens, electric water heaters and dryers can overload and trip a shared circuit when run at high power for long periods.

EMSD recommends a separate socket for each major appliance.[2] A dedicated circuit runs from the distribution board. H06 is HK$3,350 per circuit including the board connection.[1] Apply to the electricity supplier if the additional circuits raise demand above the approved loading. This is separate.[7]

Before adding a circuit, an H01 inspection can establish available board space and the condition of existing circuits.[1] An old fuse box may first needDistribution board replacement before another circuit can be added.

  • Use dedicated circuits for major appliances.
  • Check for spare board space first.
  • Apply to the supplier if the approved loading will be exceeded.
Worked example 1

Example 1: adding one socket

Assumptions

  • Add one concealed 13 A socket in the living room.

How to calculate quantities

  1. 1 × HK$640 = HK$640。[1]
  2. Below the HK$2,000 small-job minimum, so HK$2,000 applies. [1]

HK$2,000. Adding two or three points together may still leave the total close to the minimum charge.

Tiled wall work is quoted separately. [1]

Use your square footage instead and see a reference budget

05

How many sockets does a flat need? Use a schedule.

List appliances room by room and allow one or two spare points. The room layouts below reflect our team's experience, rather than statutory minimums. Adjust quantities to match your habits.

The TV wall and sofa often need four to six outlets for a television, set-top box, console, audio, router, charging and a floor lamp. Allow at least one socket on each side of the bed and another at the desk with data. A dressing table or electric heater may need another.

For a kitchen, allow two to four worktop sockets for small appliances such as a rice cooker, kettle, coffee maker and toaster. Fridges and microwaves usually have fixed positions. Assess dedicated circuits for a hob, oven and dishwasher. In a bathroom, check hair-dryer or toothbrush points against the 0.6 m clearance and applicable external switch requirements.[2]

Quantities determine the quote. For a two-bedroom example: living room, four H02 and two H03; each bedroom, three H02 and one H03; kitchen, four H02 and two H06 circuits. Total: 14 H02, four H03 and two H06. 14 × 640 + 4 × 1,200 + 2 × 3,350 = 8,960 + 4,800 + 6,700 = HK$20,460.[1] Clear quantities make quotations easier to check.

  • List appliances room by room.
  • Allow one or two spare points in each zone.
  • Plan kitchen sockets separately for small and major appliances.
  • Quantities form the basis of the quotation.
Socket planning by room

You can swipe left or right on your phone to view the complete table.

spaceCommon locationsPay attention to
Living room TV wallTelevision, set-top box, audio and networkSeparate power, television and data cables.
BedroomBoth sides of the bed, desk and wardrobeSet bedside socket height to suit the bed.
kitchenWorktop appliances, fridge and microwaveAvoid water pipes, gas pipes and cooking appliances.
Major appliancesInduction hobs, ovens and dryersUse a separate socket or dedicated circuit, as appropriate.
bathroomHair-dryer and electric toothbrush pointsAt least 0.6 m from the bathtub or shower basin. Install applicable switches outside the bathroom.
BalconyOutdoor powerUse a weatherproof socket.

For positions, refer to EMSD's Household Electrical Safety Handbook. [2] [2]

Living room with a gypsum board ceiling, warm concealed cove lighting and downlights.
Illustration of a living room gypsum board ceiling with warm concealed cove lighting and downlights · HK Create Design Select an image to enlarge

06

Adding sockets in old flats, public rental housing and new homes

Older flats may have a fuse box, too few socket circuits or no RCD protection. Adding sockets to existing circuits may not solve the underlying issue. Start with H01 inspection at HK$770, or HK$1,650 for multiple circuits. If needed, replace the board under H09 at HK$6,800 before adding points.[1] EMSD requires RCD protection for socket circuits.[2]

Electrical alterations in a public rental flat require prior approval. We can complete the application and prepare plumbing and electrical drawings for the client. Allow time for approval before work starts.

In newer flats, the board or existing conduit often has spare capacity, and additions may be possible with less chasing. Plan repairs to tiles or special finishes before cutting. In private and HOS buildings, check management rules and working hours.

  • Older flats: check the board and circuits first.
  • Public housing: apply before starting. We can submit on your behalf.
  • New flats: agree how the finishes will be reinstated.
  • Building management renovation rules
Totals for the four socket installation examples(Unit:HK$)
Kitchen: two circuits and four sockets
HK$9,260
TV wall: three H03 and two H02 points
HK$4,880
Bedroom: three H02 sockets and one H03 data point
HK$3,120
One extra socket only (minimum charge)
HK$2,000

Illustrative quantities, calculated at our published rates. [1]

Rewiring and new conduits at Royal Peninsula, Hung Hom | HK Create Design
Site photo: Electrical work at Royal Peninsula, Hung Hom, July 2026. HK Create Design. Select an image to enlarge

07

Saving money by coordinating with other works

Painting and repeat visits can add more to a small job than the socket itself. H02 and H03 include filling, but a patched chase may differ in colour from the wall, so homeowners may choose to repaint the whole wall.[1]

If painting is booked separately, E02 filling, sanding and repainting is HK$21/sq ft, minimum HK$4,650. For a 120 sq ft wall, 120 × 21 = HK$2,520, so the HK$4,650 minimum still applies.[1] But if combined with whole-flat painting orOlder flat renovation together, this forms part of the overallPainting.

Another way to reduce costs is to coordinate withPlumbing and electrical work together. If you already plan toPipe replacement, renovating the kitchen or replacing an electric water heater, coordinate the electrical work so that chasing and repairs happen once. Plan the points together to avoid a further HK$2,000 minimum for one or two additions later.[1]

  • Alongside whole-flat painting
  • Alongside plumbing and electrical works
  • Plan all points together.
New sockets and floor conduits at Dandenong Mansion, Wan Chai
Project photo, Wan Chai: concealed conduit for a wall socket, with the chase filled after installation. Select an image to enlarge

08

Concealed or surface conduit: price and appearance

H02 and H03 prices cover concealed conduit: chasing, conduit and cable, then filling, so only the faceplate remains visible.[1] The finished surface is tidy, saves space and is easy to repaint.

First, chasing tiled walls requires separately priced tile repairs and is usually best coordinated with retiling. Second, a filled chase may need repainting. Coordinate it with whole-flat painting to avoid a separate visit.

For concealed wiring, we photograph the cable routes before closing the chases and provide the photos for future fittings. EMSD requires suitable protection such as conduit for wiring in walls.[2]

  • Concealed conduit includes chasing, wiring and filling.
  • Tiled wall work quoted separately
  • Photograph wiring before the chases are closed.
Worked example 2

Example 2: three bedroom sockets and one data point

Assumptions

  • Three H02 outlets: one on each side of the bed and one at the desk.
  • One H03 data point at the desk

How to calculate quantities

  1. 3 × HK$640 = HK$1,920。[1]
  2. 1 × HK$1,200 = HK$1,200。[1]
  3. Total: 1,920 + 1,200 = HK$3,120, above the minimum.

About HK$3,120.

Networking equipment is separate. [1]

Use your square footage instead and see a reference budget
Renovation work in progress on site | HK Create Design
Renovation project photo | HK Create Design Select an image to enlarge

09

Choosing socket heights, styles and faceplates

Choose heights to suit furniture and use. Check bedhead and sofa heights so outlets stay accessible. Desk sockets often sit above the worktop. On a TV wall, coordinate the cabinet and screen height to conceal sockets behind the TV while preserving service access.

Set worktop sockets above the upstand and away from the hob and sink. Locate outlets beside or above fixed appliances such as a fridge or washing machine so they remain accessible for service. Check bathtub or shower clearance for bathroom hair-dryer sockets.[2]

Options include single, double, switched and USB sockets. Select for the intended use. We use Schneider Electric switches and sockets and can coordinate the faceplate style with theInterior design. The faceplate affects appearance. Safe wiring, circuit design and protective devices behind it remain essential.

Mark each outlet position and height on the wall with tape, then confirm with the electrician before chasing. This makes it easier to spot errors than relying on the plan alone.

  • Set the height to suit the furniture.
  • Place sockets beside or above fixed appliances.
  • Select faceplates to match the design.
  • Mark positions on site and reconfirm.
Extra sockets or long-term use of extension boards

You can swipe left or right on your phone to view the complete table.

compareAdding socketsLong-term use of extension boards
SafetyAllocate circuits according to demand and provide RCD protection.Overload risk increases when extension boards are connected in series.
AppearanceConcealed conduit gives a tidy wall finish.Exposed cables present a trip hazard.
CostFrom HK$640 per point, with a HK$2,000 minimum charge.An extension board costs less but does not resolve a shortage of permanent sockets.
EMSD guidanceGive each major appliance its own socket.Use only one adaptor or extension board per socket.

Prices are our published rates. For safety guidance see EMSD. [1][3][2] [1][3][2]

10

Should extension boards be connected in series? Official guidance

When sockets run short, avoid connecting extension boards in series. EMSD advises a maximum of one adaptor or extension board per socket to avoid overload.[3] Extension leads in regular use leave exposed cables that can cause trips or be crushed and damaged.

If tripping recurs, EMSD advises prompt inspection by a registered electrical contractor. Do not increase protective device ratings yourself.[3] Permanent extra outlets address a lack of sockets and allow circuits to be allocated by use.

Socket circuits must be protected by an RCD.[2] If the flat still has an old-style fuse box, consider assessing the board before adding sockets.

  • One extension board per socket
  • Arrange inspection if protection devices trip repeatedly.
  • Socket circuits require an RCD.
Worked example 3

Example 3: two dedicated kitchen circuits and four outlets

Assumptions

  • One dedicated circuit each for the induction hob and oven
  • Four 13 A sockets at the worktop
  • Incoming supply capacity is adequate.

How to calculate quantities

  1. 2 × HK$3,350 = HK$6,700。[1]
  2. 4 × HK$640 = HK$2,560。[1]
  3. Total: 6,700 + 2,560 = HK$9,260.

About HK$9,260.

Incoming supply upgrades, chasing in tiled walls and tile repairs are quoted separately. [7] [1][7]

Use your square footage instead and see a reference budget

11

EMSD guidance on adding electrical points

Before adding to or altering an installation, EMSD recommends engaging a registered electrical contractor to check whether the existing installation can handle the extra load.[5] Adding sockets is an addition to the installation. A registered electrical worker must inspect and test before energisation and issue WR1. [4]

EMSD guidance covers earthing, protection for wiring in walls, separation of power and communications, separate sockets for major appliances, bathroom socket clearance of at least 0.6 m from a bath or shower basin, separation from pipes and stoves, RCD protection, weatherproof outdoor sockets and applicable bathroom switches outside the room.[2]

Under EMSD's 2025 wiring code, from 1 January 2029 new installations and alterations involving a distribution board must provide arc fault detection devices (AFDDs) on socket-outlet circuits in residential flats.[6] Take the opportunity to discuss future distribution board upgrades.

  • Arrange a feasibility assessment first.
  • Test before energisation and issue WR1.
  • Follow the installation guidance.
Example socket schedule for a two-bedroom flat

You can swipe left or right on your phone to view the complete table.

spaceH02 13AH03 double socket, TV or dataH06 dedicated circuitSubtotal
Living room4 sets2 sets—4×640+2×1,200=HK$4,960
Main bedroom3 sets1 set—3×640+1,200=HK$3,120
Bedroom3 sets1 set—3×640+1,200=HK$3,120
kitchen4 sets—2 circuits4×640+2×3,350=HK$9,260
Total14 sets4 sets2 circuitsHK$20,460

Illustrative quantities calculated using our published rates. [1] [1]

New electricity meter box and main switch in a Tai Wai village house
Site photo: New electricity meter box and main switch installed in a village house in Tung Lo Wan Village, Tai Wai, July 2026. HK Create Design. Select an image to enlarge

12

Common issues in socket installation quotations

First, specify concealed or surface conduit so the finish is clear. Second, agree whether filling and repainting are included. Third, record the small-job minimum, which can apply to each separate visit for one or two outlets.

Fourth, putting high-load kitchen appliances on an unsuitable shared circuit can cause repeated trips. Fifth, avoid bathroom sockets too close to the shower.[2] Sixth, obtain WR1. Adding a socket is an addition to a fixed electrical installation and requires a completion certificate.[4]

Before work starts, specify each point's type, position and method, exclusions and WR1 arrangements in the quotation and contract.

  • Specify concealed conduit.
  • Specify the extent of making good.
  • Dedicated circuits for major appliances
  • Bathroom clearance
  • Specify WR1.
Site photo of floor channels for pipework at Yat Man House, Ho Man Tin Estate | HK Create Design
Project photograph: plumbing at Yat Man House, Ho Man Tin Estate, May 2026, HK Create Design Select an image to enlarge

13

Handover: testing new sockets

First, test each socket with a small appliance, including both sides of double outlets. Second, test data points with a computer. Third, check the visible board labels for any new circuits.[2] Fourth, use the RCD test button and confirm that it trips.

Fifth, check that the filled chase is level and the faceplate straight. Sixth, collect the original WR1 and cable route photos.

We use Schneider Electric socket faceplates and typically Hilly or ei8ht cables with product certifications such as 3C. We install to the EMSD wiring code and provide WR1 on completion. Work has a one-year warranty, excluding deliberate damage.

  • Test each socket.
  • Test data connectivity.
  • Circuit labels
  • Obtain WR1.
Worked example 4

Example 4: three H03 and two H02 points at the TV wall

Assumptions

  • One H03 each for the TV, data and double socket
  • Two H02 outlets, one on each side

How to calculate quantities

  1. 3 × HK$1,200 = HK$3,600。[1]
  2. 2 × HK$640 = HK$1,280。[1]
  3. Total: 3,600 + 1,280 = HK$4,880.

About HK$4,880.

TV wall joinery and concealed cable channels are priced separately. [1]

Use your square footage instead and see a reference budget

14

Book a quote for additional sockets.

For a free quotation from the HK Create Design team, WhatsApp 5243 7747 or visit our Wong Tai Sin shop, Monday to Saturday, 10:00–18:00.

For a few points, mark the positions on photos and send them via WhatsApp for a preliminary quote. Small jobs carry a HK$2,000 minimum.[1] Book a visit when this work is combined with other items. On-site measurement is free through 31 December 2026 for two or more work items, with no deposit. After that, the HK$500 fee is credited against the order.

The quote lists H02, H03 and H06 quantities and locations, exclusions and WR1 arrangements.

  • Mark the positions on photos and send them on WhatsApp.
  • List the appliances you want to add.
  • Mark out all positions together.

Advice from our tradespeople

「Agree furniture positions before adding outlets. Bedheads, desks, media units and kitchen worktops often lack enough sockets.」

HK Create Design electrical works supervisorHK Create Design project team

「Bathroom sockets must meet clearance requirements from baths and showers and have earth leakage protection.」

HK Create Design's partner registered electrical contractorHK Create Design's partner electrical subcontractor

「We mark each outlet on the floor plan and seek confirmation before chasing, so the finished positions fit the room.」

Project Manager, HK Create DesignHK Create Design project team

FAQ

12 practical questions answered

01What does it cost to add one socket?

H02 is HK$640 per point. A job for one point alone is charged at the HK$2,000 small-job minimum.[1]

02What does a double socket cost?

H03 double socket, TV or data point: HK$1,200 each.[1]

03How much does an extra dedicated circuit cost?

H06 is HK$3,350 per circuit including connection at the board. Increased incoming capacity is separate.[1]

04Does the price include filling and painting?

Chase filling is included. Repainting is usually separate, and work on tiled walls requires a separate price.[1]

05Can I add a bathroom socket?

Yes, subject to the minimum 0.6 m distance from the bathtub or shower basin and the applicable switches being outside the bathroom.[2]

06Where should kitchen sockets go?

Avoid water pipes, gas pipes and cooking appliances. Use a separate socket for each major appliance.[2]

07Can I use an extension board instead?

EMSD advises using one adaptor or extension board per socket and avoiding chained extension boards.[3]

08How long does adding a socket take?

Usually within one day. Painting is separate.

09Does an extra socket require WR1?

Yes. This is installation work requiring inspection and testing before energisation and issue of WR1.[4]

10Can I add a balcony socket?

Yes. Use a weatherproof socket outdoors.[2]

11Which socket brands do you use?

Schneider Electric switches and sockets, with Hilly or ei8ht cables. We use cable brands with product certifications such as 3C, install to the EMSD wiring code and provide WR1 at completion.

12How can I make an appointment?

Send photos to HK Create Design on WhatsApp 5243 7747 for an initial quotation. On-site measurement is free through 31 December 2026 for two or more work items, with no deposit. After that, the HK$500 fee is credited against the order.

CHECK THE BASIS

Data and technical basis, sources can be verified

  1. [1]HK Create Design 2026 published rates: electrical work H01–H09 Accessed: 2026-11-03
  2. [2]EMSD Household Electrical Safety Handbook: general tips for electrical installations Accessed: 2026-11-03
  3. [3]Electrical and Mechanical Services Department: safe use and maintenance of electrical installations Accessed: 2026-11-03
  4. [4]Electrical and Mechanical Services Department: Household Electrical Safety Handbook, new installations, additions and alterations Accessed: 2026-11-03
  5. [5]Electrical and Mechanical Services Department: new electrical installations, additions and alterations Accessed: 2026-11-03
  6. [6]EMSD: summary of revisions to the Code of Practice for the Electricity (Wiring) Regulations, 2025 edition Accessed: 2026-11-03
  7. [7]CLP Power: changing the approved loading for residential customers Accessed: 2026-11-03